YIME-AgR15-8040 Technical Specifications
| Effective Membrane Area | 400 ft² (37.2 m²) |
| Permeate Flow | 945 L/h (22.7 m³/day) |
| Cyanide Removal Rate | 94.5% |
| Molecular Weight Cut-Off | 100 Da |
| Operating Pressure | 2.5 MPa (363 psi) |
| Maximum Operating Temperature | 40°C |
| Maximum Feed Flow | 15 m³/h |
| Maximum Pressure Drop | 1 kg/cm² |
| Minimum Concentrate : Permeate Ratio | 5:1 |
| Element Length | 40 inch |
| Element Diameter | 8 inch |
| Center Tube Diameter | 1.125 inch |
| Weight | 12 kg |
| Feed Spacer Width | 30 mil |
The 94.5% cyanide removal rate is based on the specified standard test conditions and should not be interpreted as a guaranteed result for every wastewater composition.
The test was conducted using a 1,000 ppm cyanide solution as the feed solution at a temperature of 25 ± 5°C and a pH of 11.5. The measured recovery was 15 ± 5%, with a maximum feed SDI of 5.
|
Application Configuration
The Silver Ion Separation Membrane (YIME-AgR15-8040) is commonly used in silver concentration systems to recover silver from silver-containing wastewater generated during silver plating processes, such as LED frame plating. The membrane element must be installed inside a pressure vessel, typically an FRP (fiberglass-reinforced plastic) membrane housing, for proper operation. A silver concentration system is typically integrated with the following water treatment processes: 1.Pretreatment System
Pretreatment is the first stage of a silver-containing wastewater treatment process. Depending on the feed water quality, suspended solids, particles, oil, and other potential contaminants should be removed or reduced as much as possible before the wastewater enters the silver recovery membrane system. Effective pretreatment helps reduce membrane fouling and potential membrane damage, improving the reliability and long-term stability of the system. The pretreatment system typically includes a feed water storage tank for collecting and storing silver-containing wastewater, helping stabilize the feed flow rate and water quality. The silver concentration membrane system can be connected directly downstream of the storage tank. Depending on the feed water quality, activated carbon filters, sand filters, cartridge filters, or other solid-liquid separation equipment may also be included.
In some applications, additional pretreatment measures are required to protect the downstream water treatment system. These may include antiscalant dosing to reduce the risk of membrane scaling, a chemical cleaning system, and treatment processes for removing oxidizing agents, organic solvents, or other substances that could damage the membrane material.
2. Electrolysis System
The electrolysis system is installed downstream of the silver concentration system and is connected to the concentrate line from the membrane system. It is used to further recover silver from the high-concentration silver-containing solution produced by the silver ion concentration membrane.
A typical electrolysis system consists of an electrolytic cell, cathode and anode plates, a DC power supply, circulation equipment, piping, and a control system. The main components of a typical electrolysis system are shown in the figure below.
The electrolysis system can be configured according to the silver concentration, flow rate, and target recovery capacity of the concentrate. After the wastewater is concentrated through a single-stage or multi-stage membrane process using YIME-AgR15-8040,YIME-AgR100-8040, or other silver ion concentration membranes, the silver ion concentration is significantly increased. The resulting concentrate is then fed into the electrolytic cell, where metallic silver is recovered through electrolysis.
Combining membrane concentration with electrolysis avoids directly electrolyzing large volumes of low-concentration silver-containing wastewater. This can improve silver recovery efficiency while reducing overall energy consumption.
circulation equipment
control system
circulation equipment
3.Reverse Osmosis System
After treatment with the Silver Ion Separation Membrane (YIME-AgR15-8040), the silver-containing wastewater is separated into two streams: a silver-rich concentrate from the concentrate side and permeate water from the permeate side.
When there is no need for water reuse, the permeate can be discharged directly in accordance with applicable discharge requirements. If the process requires water reuse, the permeate can be further treated by a reverse osmosis (RO) system for reuse as process water.
For further treatment, the permeate can be processed using an RO Membrane 8040 or an Industrial RO Membrane ULP-BW-8040-FR, depending on the required water quality and system configuration.
4.EDI (Electrodeionization) Equipment When reclaimed water must meet specific limits for ion concentration or conductivity, a deionization or desalination system can be added downstream of the membrane treatment process. Electrodeionization (EDI) is an advanced purification device that uses an electric field, ion exchange resins, and ion exchange membranes to continuously remove ionic impurities from water. It is typically installed after a reverse osmosis (RO) system to further reduce ion concentration and conductivity, producing stable high-purity or ultrapure water. Unlike traditional ion exchange systems, which require periodic regeneration with acids and bases, EDI uses a DC electric field to achieve continuous desalination-eliminating the need for chemical regeneration, enabling continuous operation, and offering a high degree of automation. |
Hot Tags: the silver ion separation membrane yime-agr15-8040, China the silver ion separation membrane yime-agr15-8040manufacturers, suppliers, factory, advanced reverse osmosis membrane, best brand of ro membrane, reverse osmosis membrane for total dissolved solids control, ro membrane filter, ro membranes for sale, wastewater treatment membrane